Coax HP Limiters
This series of high power limiters was developed to protect sensitive receiver circuits from close proximity threats (e.g. high power radar or communicationtransmitters). The standard models handle up to 60W CW while the higher power models can handle up to 100W CW. All models handle 1000W peak andexhibit low insertion loss and leakage levels. The limiters are available in either type N (male-to-male) or SMA connector versions.
 
Frequnecy Range (MHz) Part number Peak Input Power (kW)*(5) CW Input Power (watts)*(1,5) maximun Flat Leakage (CW Power)(dBm) maximum Insertion Loss (dB) Maximum VSWR Standard Case Style Case Styles
0.5 - 30 ACLM4869 1 60 14 0.1 1.25:1 C46 C24,C25,C88,C89
30 - 100 ACLM4870 1 60 14 0.1 1.25:1 C46 C24,C25,C88,C89
10 - 500 ACLM4827 1 60 14 0.1 1.25:1 C46 C24,C25,C88,C89
100 - 500 ACLM4930 1 60 14 0.2 1.25:1 C46 C24,C25,C88,C89
100 - 1000 ACLM4871 1 60 14 0.2 1.28:1 C46 C24,C25,C88,C89
200 - 1000 ACLM4903 1 60 14 0.2 1.28:1 C46 C24,C25,C88,C89
1200 - 1400 ACLM4603 1 60 14 0.25 1.25:1 C46 C24,C25,C88,C89
2 – 1500 ACLM4932 1 60 14 0.25 1.25:1 C46 C24,C25,C88,C89
200 - 1500 ACLM4904 1 60 14 0.25 1.25:1 C46 C24,C25,C88,C89
0.1 - 2000 ACLM4897 1 60 14 0.3 1.25:1 C46 C24,C25,C88,C89
1-2000 ACLM4874 1 60 14 0.3 1.25:1 C46 C24,C25,C88,C89
20 - 2000 ACLM4924 1 60 13 0.35 1.25:1 C46 C24,C25,C88,C89
500 - 2000 ACLM4947 1 60 14 0.35 1.25:1 C46 C24,C25,C88,C89
1000 - 2000 ACLM4851 1 60 14 0.35 1.25:1 C46 C24,C25,C88,C89
2-2500 ACLM4918 1 60 13 0.38 1.25:1 C46 C24,C25,C88,C89
0.1 - 3000 ACLM4896 1 60 13 0.4 1.25:1 C46 C24,C25,C88,C89
500 - 3000 ACLM4829 1 60 13 0.5 1.25:1 C46 C24,C25,C88,C89
2000 - 3000 ACLM4828 1 60 13 0.5 1.25:1 C46 C24,C25,C88,C89
600 - 3100 ACLM4891 1 60 13 0.5 1.25:1 C46 C24,C25,C88,C89
2700 - 3100 ACLM4852 1 60 13 0.5 1.25:1 C46 C24,C25,C88,C89
3000 - 3700 ACLM4905 1 60 13 0.8 1.9:1 C46 C24,C25,C88,C89
2000 - 4000 ACLM4943 1 60 13 1.2 2.0:1 C46 C24,C25,C88,C89

Features:
• Low Insertion Loss
• low Leakage Power Circuit Protection
• High CW Power Handling
• Assorted Package Styles

Notes:
1) All models rated for 60W CW are available as 100W CW versions. The part number requires the suffix "H" addedfollowing the part number to indicate high power rating.
2) Test Conditions: Full rated power for 10 seconds
3) Insertion Loss is slightly higher for the high power versions
4) Most models are broadband and will operate beyond the frequency ranges shown
5) Typical leakage is 3dB below the maximum shown
6) Power handling is linearly derated from full power at +25 ?C to zero power at +150 ?C
7) All models require external DC blocks for proper operation